Mitsubishi Electric · FR-A800Fault Code E.OV1Warning
Mitsubishi FR-A800 — E.OV1 DC Bus Overvoltage
Occurs when the DC bus exceeds the upper limit. Fast deceleration and regenerative energy are the main causes.
Updated: 2026-07-05
Symptoms
- E.OV1 on deceleration
- Recurs on high-inertia loads
- Occurs when supply is high
Probable Causes
- Too-short deceleration time (Pr.8)
- No brake resistor/unit
- Supply overvoltage
Checkpoints
- Increase deceleration time (Pr.8)
- Check the brake unit/resistor
- Measure supply voltage
Solution
First extend the deceleration time; add a brake unit for frequent stops.