Skip to content
ELKAR
Schneider Electric · Altivar ATV320Fault Code OHFWarning

Schneider Altivar — OHF Drive Overheat

Occurs when the drive heatsink exceeds the limit. Fan, airflow or ambient temperature are the main causes.

Updated: 2026-07-05

Symptoms

  • OHF after long operation
  • Frequent in hot cabinets
  • Fan weak/stopped

Probable Causes

  • Fan faulty/dusty
  • Air duct blockage
  • High ambient temperature

Checkpoints

  • Verify fan and airflow
  • Clean the heatsink
  • Measure ambient temperature

Solution

The fan is replaced with an equivalent. If a temperature-sensor fault is suspected, the board is tested.

Related Products

Related Faults

Facing the same issue?

Send your faulty board to our lab or consult our expert team. Free pre-analysis.

+90 543 855 16 44 · info@elkarotomasyon.com