Skip to content
ELKAR
Siemens · SINAMICS G120Fault Code F30004Warning

Siemens SINAMICS G120 — F30004 Power Unit Overtemperature

Occurs when the heatsink temperature exceeds the limit. Poor cooling, a clogged fan or high ambient temperature are the main causes.

Updated: 2026-07-05

Symptoms

  • F30004 after prolonged operation
  • Frequent in summer / hot cabinets
  • Fan noise weak or absent

Probable Causes

  • Cooling fan faulty or clogged with dust
  • Cabinet, filter or air duct blockage
  • High ambient temperature
  • Continuous operation at overload

Checkpoints

  • Verify the fan spins and airflow is present
  • Clean the heatsink and fan blades
  • Measure cabinet ventilation and ambient temp
  • Review the load/current profile

Solution

A faulty fan is replaced with an original equivalent. If a temperature sensor/measurement fault is suspected, the board is tested in the lab.

Related Products

Related Faults

Facing the same issue?

Send your faulty board to our lab or consult our expert team. Free pre-analysis.

+90 543 855 16 44 · info@elkarotomasyon.com